A business that welds must keep its workers’ exposure to welding fumes, and to each component of those fumes, below the legal limit. Safe Work Australia lists the Workplace Exposure Standard (WES) for welding fumes at 1 mg/m³ as an eight-hour average, down from 5 mg/m³. Your Safe Work Method Statement (SWMS) covers how the job is done and controlled. It does not replace the controls or air monitoring.
What are welding fumes?
Welding fumes are a mix of metal particles and gases. What is in them depends on the process, the base metal, the rods or wire, and any paint, coating or contamination on the metal. Stainless steel, galvanised steel, painted steel and aluminium all produce different fumes, so two welders in the same shed can face different hazards.
Safe Work Australia says the reduced limit is there to better protect workers from health effects including lung cancer and other lung disease.
What is the limit?
According to Safe Work Australia’s welding fumes page:
- Welding fumes (not otherwise classified): 1 mg/m³, measured as total fume in the worker’s breathing zone over an eight-hour day, five-day week.
- Aluminium (welding fumes): 1 mg/m³ on the same basis.
- The individual components of the fume, and any gases and vapours released, have their own limits. You must keep each of them under its limit too.
Both were reduced from 5 mg/m³. Safe Work Australia says the reduced limit takes effect when implemented in a jurisdiction, so ask your regulator how it applies where you work.
The limit is a legal maximum, not an acceptable level. The WHS laws still require you to eliminate or minimise the risk as far as is reasonably practicable.
What changes when WES become WEL?
From 1 December 2026, Workplace Exposure Standards become Workplace Exposure Limits (WEL), following implementation in each jurisdiction. The model Code of Practice: Welding processes has been amended to use the new term. For what the change means across all substances, see what are WES and WEL?
Two points matter for welders:
- Chromium VI. Chromium VI compounds are among 33 non-threshold genotoxic carcinogens that will no longer have a numeric limit from 1 December 2026. Where they are present, for example from stainless steel or chromate coatings, you must eliminate, substitute or reduce the risk as far as is reasonably practicable.
- Victoria. WorkSafe Victoria has a transition to 1 December 2029 for 15 substances, including manganese fume, dust and compounds. Check WorkSafe Victoria’s quick reference table for the manganese limit that applies today.
Take any figure for a fume component from the official exposure limits list or your regulator, not from a supplier flyer or forum post.
How do you control welding fume?
Work up the hierarchy of controls. The model Code of Practice: Welding processes covers this in detail, and Appendix B lists the chemicals that welding can produce.
- Eliminate or substitute. Choose a process, consumable or base metal that produces less fume. Strip coatings before welding where you can.
- Engineering controls. On-torch extraction, local exhaust ventilation and general ventilation, especially indoors and in tight spaces.
- Administrative controls. Positioning so the welder’s head stays out of the plume, limiting time on high-fume work, and keeping other workers out of the area.
- Respiratory protection. A respirator suited to the fume, fit tested, and used as the last line, not the first.
If you are not sure the controls are keeping exposure under the limit, the WHS laws require air monitoring. The safety data sheet (SDS) for the rods or wire is a good start for working out what is in the fume.
What goes in a welding SWMS?
A SWMS is required for high risk construction work. Welding on a construction site often falls into one or more of the categories, for example work at height over 2 metres, in or near a confined space, in an area with a contaminated or flammable atmosphere, or where powered mobile plant is moving. Fabrication in your own workshop is usually not construction work, so the SWMS rule may not apply there, though a client may still ask for one.
For the welding task, the SWMS should cover:
- The process, base metals, consumables and any coatings involved.
- The fume, gas, fire and burn hazards, plus electrical hazards from the set.
- The extraction and ventilation you will use, and how you check they work.
- Respiratory protection, fit testing and when it is worn.
- Hot work controls: fire watch, screens, removal of flammables, and any hot work permit.
- Who supervises, and how the controls are monitored and reviewed.
Some things sit beside the SWMS rather than in it: air monitoring results, the hazardous chemicals register, the SDS and any health monitoring records. For how to set out the document, see how to write a SWMS. For the wider risk process, see what is a risk assessment?
Welding and fabrication pack
The Welding and Fabrication trade pack includes 14 SWMS, among them Welding & Hot Works, Oxy Cutting & Heating, Hazardous Substances, On-Site Steel Fabrication & Modification and Abrasive Blasting. It is $249.99 per state, editable Word, one-off purchase.
Add your own process, consumables, extraction set-up and monitoring results before using it. If you also strip or coat metal, the Painting pack covers surface preparation, spray painting and lead paint removal. Not sure which fits? See which SWMS pack do I need?
Common questions
What is the exposure standard for welding fumes?
Safe Work Australia lists 1 mg/m³ for welding fumes (not otherwise classified) and 1 mg/m³ for aluminium welding fumes, as an eight-hour average over a five-day week. That was reduced from 5 mg/m³ and takes effect when implemented in each jurisdiction, so check with your regulator.
Is staying under 1 mg/m³ enough?
No. You must also keep each component of the fume, and any gases released, under its own limit. And you must reduce exposure as far as is reasonably practicable, not just get under the number.
Do I need air monitoring for welding?
If you are not sure whether anyone is exposed above a limit, the WHS laws require air monitoring. The safety data sheets for your rods and wire help identify what is in the fume.
What happens to chromium VI from 1 December 2026?
Chromium VI compounds are one of 33 non-threshold genotoxic carcinogens that will no longer have a numeric limit. You must eliminate, substitute or reduce the risk as far as is reasonably practicable. Until then, the current exposure standard still applies.
Sources: Safe Work Australia—Welding fumes, Model Code of Practice: Welding processes, Changes between the WES and WEL and WorkSafe Victoria—Workplace exposure standards and limits. General information only; check the limits that apply in your jurisdiction with your regulator.
Start from a proper SWMS, not a blank page
State-specific, editable templates written for your state. Download instantly, then make it yours for the job and the site.